Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters

Language
Document Type
Year range
1.
medrxiv; 2021.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2021.03.24.21254240

ABSTRACT

BackgroundVaccine-induced population immunity is a key global strategy to control coronavirus disease 2019 (COVID-19). The rapid implementation and availability of several COVID-19 vaccines is now a global health-care priority but more information about humoral responses to single- and double-dose vaccine is needed Methods163 health care workers (HCW) of the Padua University Hospitals, who underwent a complete vaccination campaign with BNT162b2 vaccine were asked to collect serum samples at 12 (t12) and 28 (t28) days after the first inoculum to allow the measurement of SARS-CoV-2 Antibodies (Ab) using chemiluminescent assays against the spike (S) protein and the Receptor Binding Domain (RBD) of the virus, respectively. ResultsSignificant differences were found at t12 for infection-naive and subjects with previous-natural infection who present higher values of specific antibodies, while no significant differences have been found between t12 and t28. No statistically significant difference was found between male and female, while lower Ab levels have been observed in subjects older than 60 years at t12 but not at t28. ConclusionsOur study confirms observed differences in vaccine responses between infection-naive and subjects with previous natural infection at t12 but not for a longer time. The influence of sex and age deserves further studies, even if the relationship with age seems particularly significant.


Subject(s)
COVID-19
2.
medrxiv; 2021.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2021.03.10.21253260

ABSTRACT

Background SARS-CoV-2 serology presents an important role in understanding the virus epidemiology, in vaccine prioritization strategies and in convalescent plasma therapy. Immunoassays performances have to be accurately evaluated and correlated with neutralizing antibodies to be used as a surrogate measure of neutralizing activity. We investigate the analytical and clinical performance of a SARS-CoV-2 RBD IgG assay, automated on a high throughput platform, and the correlation of the antibodies (Ab) levels with the plaque reduction neutralization (PRNT 50 ) Ab titers. Methods A series of 546 samples were evaluated by SARS-CoV-2 RBD IgG assay (Snibe diagnostics), including 171 negative and 168 positive SARS-CoV-2 subjects and a further group of 207 subjects of the COVID-19 family clusters follow-up cohort. Results Assay precision was acceptable at low and medium levels; linearity was excellent in all the measurement range. Considering specimens collected after 14 days post symptoms onset, overall sensitivity and specificity were 99.0% and 92.5%, respectively. A total of 281 leftover samples results of the PRNT 50 test were available. An elevated correlation was obtained between the SARS-CoV-2 RBD IgG assay and the PRNT 50 titer at univariate (rho = 0.689) and multivariate (rho = 0.712) analyses. Conclusions SARS-CoV-2 S-RBD IgG assay achieves elevated analytical and clinical performances, and a strong correlation with sera neutralization activity.


Subject(s)
COVID-19
3.
medrxiv; 2020.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2020.12.24.20248825

ABSTRACT

Background SARS-CoV-2 quick testing and reporting are now considered relevant for the containment of new pandemic waves. Antigen testing in self-collected saliva might be useful. We compared the diagnostic performance of salivary and naso-pharyngeal swab (NPS) SARS-CoV-2 antigen detection by a rapid chemiluminescent assay (CLEIA) and two different point-of-care (POC) immunochromatographic assays, with that of molecular testing. Methods 234 patients were prospectively enrolled. Paired self-collected saliva (Salivette) and NPS were obtained to perform rRT-PCR, chemiluminescent (Lumipulse G) and POC (NPS: Fujirebio and Abbott; saliva: Fujirebio) for SARS-CoV-2 antigen detection. Results The overall agreement between NPS and saliva rRT-PCR was 78.7%, reaching 91.7% at the first week from symptoms onset. SARS-CoV-2 CLEIA antigen was highly accurate in distinguishing between positive and negative NPS (ROC-AUC=0.939, 95%CI:0.903-0.977), with 81.6% sensitivity and 93.8% specificity. This assay on saliva had an overall good accuracy (ROC-AUC=0.805, 95%CI:0.740-0.870), reaching the optimal value within 7 days from symptom onset (Sensitivity: 72%; Specificity: 97%). POC antigen in saliva had a very limited sensitivity (13%), performing better in NPS (Sensitivity: 48% and 66%; Specificity: 100% and 99% for Espline and Abbott respectively), depending on viral loads. Conclusions Self-collected saliva is a valid alternative to NPS for SARS-CoV-2 detection not only by molecular, but also by CLEIA antigen testing, for which the highest diagnostic accuracy was achieved in the first week from symptom onset. Saliva is not suitable for POC, although the accuracy of these tests appears satisfactory for NPS with high viral load.


Subject(s)
Pharyngitis
4.
biorxiv; 2020.
Preprint in English | bioRxiv | ID: ppzbmed-10.1101.2020.12.25.424300

ABSTRACT

Gut microbiota plays a critical role in the induction of adaptive immune responses to influenza virus infection. However, the role of nasal bacteria in the induction of the virus-specific adaptive immunity is less clear. Here we demonstrate that while intranasal administration of influenza virus hemagglutinin vaccine alone was insufficient to induce the vaccine-specific antibody responses, disruption of nasal bacteria by lysozyme or addition of culturable oral bacteria from a healthy human volunteer rescued inability of the nasal bacteria to generate antibody responses to intranasally administered the split-virus vaccine. Myd88-depdnent signaling in the hematopoietic compartment was required for adjuvant activity of intranasally administered oral bacteria. In addition, we found that the oral bacteria-combined intranasal vaccine induced protective antibody response to influenza virus and SARS-CoV-2 infection. Our findings here have identified a previously unappreciated role for nasal bacteria in the induction of the virus-specific adaptive immune responses.


Subject(s)
COVID-19 , Influenza, Human
5.
medrxiv; 2020.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2020.11.20.20235267

ABSTRACT

BackgroundO_ST_ABSAbstractC_ST_ABSReliable SARS-CoV-2 serological assays are required for diagnosing infections, for the serosurveillance of past exposures and for assessing the response to future vaccines. In this study, the analytical and clinical performances of a chemiluminescent immunoassays for SARS-CoV-2 IgM and IgG detection (Mindray CL-1200i), targeting Nucleocapsid (N) and receptor binding domain (RBD) portion of the Spike protein, were evaluated. MethodsPrecision and linearity were evaluated using standardized procedures. A total of 157 leftover serum samples from 81 hospitalized confirmed COVID-19 patients (38 with moderate and 43 with severe disease) and 76 SARS-CoV-2 negative subjects (44 healthcare workers, 20 individuals with rheumatic disorders, 12 pregnant women) were included in the study. In an additional series of 44 SARS-CoV-2 positive, IgM and IgG time kinetics were also evaluated in a time-period of 38 days. ResultsPrecision was below or equal to 4% for both IgM and IgG, in all the studied levels, whilst a slightly significant deviation from linearity was observed for both assays in the range of values covering the manufacturers cut-off. Considering a time frame [≥] 12 days post symptom onset, sensitivity and specificity for IgM were 92.3% (95%CI:79.1%-98.4%) and 92.1% (95%CI:83.6%-97.0%). In the same time frame, sensitivity and specificity for IgG were 100% (95%CI:91.0%-100%) and 93.4% (95%CI:85.3%-97.8%). The assays agreement was 73.9% (Cohens kappa of 0.373). Time kinetics showed a substantial overlapping of IgM and IgG response, the latter values being elevated up to 38 days from symptoms onset. ConclusionsAnalytical imprecision is satisfactory as well as the linearity, particularly when taking into account the fact that both assays are claimed to be qualitative. Diagnostic sensitivity of IgG was excellent, especially considering specimens collected [≥]12 days post symptom onset. Time kinetics suggest that IgM and IgG are detectable early in the course of infection, but the role of SARS-CoV-2 antibodies in clinical practice still requires further evaluations.


Subject(s)
Severe Acute Respiratory Syndrome , COVID-19
6.
medrxiv; 2020.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2020.08.01.20166546

ABSTRACT

BackgroundReliable high-throughput serological assays for SARS-CoV-2 antibodies (Abs) are urgently needed for the effective containment of the COVID-19 pandemic, as it is of crucial importance to understand the strength and duration of immunity after infection, and to make informed decisions concerning the activation or discontinuation of physical distancing restrictions. MethodsIn 184 serum samples from 130 COVID-19 patients and 54 SARS-CoV-2 negative subjects, the analytical and clinical performances of four commercially available chemiluminescent assays (Abbott SARS-Cov-2 IgG, Roche Elecsys anti-SARS-CoV-2, Ortho SARS-CoV-2 total and IgG) and one enzyme-linked immunosorbent assay (Diesse ENZY-WELL SARS-CoV-2 IgG) were evaluated and compared with the neutralization activity achieved using the plaque reduction neutralization test (PRNT). FindingsPrecision results ranged from 0.9% to 11.8% for all assays. Elecsys anti-SARS-CoV-2 demonstrated linearity of results at concentrations within the cut-off value. Overall, sensitivity ranged from 78.5 to 87.8%, and specificity, from 97.6 to 100%. On limiting the analysis to samples collected 12 days after onset of symptoms, the sensitivity of all assays increased, the highest value (95.2%) being obtained with VITRO Anti-SARS-CoV-2 Total and Architect SARS-CoV-2 IgG. The strongest PRNT50 correlation with antibody levels was obtained with ENZY-Well SARS-CoV-2 IgG (rho = 0.541, p < 0.001). InterpretationThe results confirmed that all immunoassays had an excellent specificity, whereas sensitivity varied across immunoassays, depending strongly on the time interval between symptoms onset and sample collection. Further studies should be conducted to achieve a stronger correlation between antibody measurement and PRNT50 in order to obtain useful information for providing effective passive antibody therapy, and developing a vaccine against the SARS-CoV-2 virus.


Subject(s)
COVID-19
7.
medrxiv; 2020.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2020.04.27.20073858

ABSTRACT

We investigated the SARS-CoV-2 specific antibody titers in 133 asymptomatic healthcare providers working at the Department of Laboratory Medicine of our tertiary center. A commercial chemiluminescence immunoassay, validated according to the ISO15189 standard requirements, was used. All the enrolled healthcare professionals underwent, simultaneously to the blood sampling, a nasopharyngeal swab for molecular testing with quantitative reverse-transcriptase-based polymerase chain reaction (RT-PCR). An overall positiveness of 5.25% was found. We strongly promote a wide use of validated serologic assays in asymptomatic, healthy individuals, as a crucial information for epidemiological surveillance.

SELECTION OF CITATIONS
SEARCH DETAIL